omni
nfpa

Items per page:
34 Companies with Results for dust explosion 1 - 10 of 34

Flamex Inc.

4365 Federal Dr. Greensboro, NC 27410 Tel: 336-299-2933

View company website
8 More Results

My Website > solutions flamex

... are the primary piece of equipment associated with dust explosions. It is estimated that 70-80% of all industrial explosions where combustible dusts are handled are generated within a dust collector. ...

News, Press Releases & Industry Articles

... LA chooses Minifog PressProtect Preventable Wood Pellet Plant Dust Explosion - courtesy of Woodworking Network Georgia Pacific Hosford, FL ... Presses FLAMEX Systems help Reduce the Risks of Dust Fires and Explosions MINIFOG Fire Protection To Save Your Press Frequency ...

Flamex Spark Detection & Extinguishing Systems

... the Day-The Herald Preventable Wood Pellet Plant Dust Explosion- courtesy of Woodworking Network The only North American ...

My Website > products backdraft dampers

... upstream in ductwork in the event of a dust collector explosion. It is installed on the ductwork upstream of a dust collector. The unit contains a flap that is ...

My Website > videos

... sense, cost effective measure for the prevention of dust collector fires and explosions. MINIFOG Suppression: Cooling and Suffocating Effect See a demonstration of the effective suppression capability Minifog PressProtect System ... Combustible Dust Hazard Learn more about the dangers of combustible ...

About Flamex, Inc

... filtration systems. To combat the common problem of dust collector fires and explosions, our company pioneered the utilization of a new ...

Prevent Fires and Explosions In Pneumatic Conveying, Air Filtration And Dust Collecting Systems

... be of assistance to your company. "If combustible dusts are collected, there is a fire and explosion hazard in the collector regardless of the bag ...

My Website > faqs

... our facility from any possibility of fire or explosion associated with the dust collection system? No system can provide a 100% protection guarantee against all possible incidences of fires and explosions. Certainly there can be ignition sources and hazard ...

close more results

FLAMEX® is the worlds premier spark detection and extinguishing system. It is also the first ...

GreCon, Inc.

15875 SW 74th Avenue Tigard, OR 97224 Tel: 503-641-7731

View company website

REDUCE YOUR RISK OF FIRES AND DUST EXPLOSIONS. Spark and ember generation is a ...

About Us - Chilworth Technology

... laboratory testing facilities with state of the art dust explosion and electrostatic laboratories (with low humidity facility), and ...

Combustible Dust Testing - Chilworth Technology

... provides safety services to industry to help PREVENT dust explosions and PROTECT against their effects. Industrial dust explosions occur frequently. They cause loss of life, injury, ...

Guide to Dust Explosion Hazards - Chilworth Technology

Guide to Dust Explosion Hazards Every year explosions caused by combustible dust kill workers, damage assets, and leave others badly injured. To ... risks, organizations that have the potential to produce explosive dust atmospheres should evaluate the flammability of that dust, ...

Additions to NFPA 61 - Chilworth Technology

... 61, Standard for the Prevention of Fires and Dust Explosions in the Agricultural and Food Processing Industries Facilities ... 61, Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities as a ...

Safety Insight - Feb 2017 - Chilworth Technology

Safety Insight - Feb 2017 A Filter/Receiver Dust Explosion A filter/receiver directly connected to a powder milling operation exploded giving rise to an indoor deflagration, which, fueled by powder deposits, propagated ...

Establishing a Housekeeping Program for Combustible Dusts - Chilworth Technology

... Board and other agencies who have investigated serious dust explosions over the last 30 years have found a ... levels, the plant becomes at risk for secondary dust explosions. Next Steps Contact Us Request A Quote Featured ...

OSHA Combustible Dust NEP Services - Chilworth Technology

... Hazard Investigation Board (CSB) had found that “...combustible dust explosions are a serious hazard in American industry, and ... ... and literature to assess the magnitude of the dust explosion hazard and found that 281 combustible dust incidents ...

NFPA Compliance - Chilworth Technology

... 61 Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities NFPA 68 ... 654 Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible ...

Safety Insight - Jul 2017 - Chilworth Technology

Safety Insight - Jul 2017 The Dangers of Using Dust Explosion Data from “Public” Sources When assessing the fire ... could result in underestimating the ignition sensitivity and explosion ... a representative dust sample from the facility or process equipment and ...

Process Safety Training - Chilworth Technology

... Safety Excellence Lessons from Accidents in Process Industries Dust Explosions Gas/Vapor Explosions Chemical Reaction and Thermal Stability ...

DEKRA Process Safety Americas Newsletter - May 2017 - Chilworth Technology

... and safety system specification, design and implementation. 2. Dust Fires and Explosions Caused by Self-Heating - A Complicated but Predictable ... combustion of powders can give rise to significant dust fire and explosion hazards particularly where bulk storage, hot material stacking, ...

DEKRA Process Safety Americas Newsletter - Jan 2017 - Chilworth Technology

... program is an essential component of effective combustible dust fire and explosion hazard control. Using appropriate process information, material (powder/ ...

Completing a Dust Hazard Analysis - Chilworth Technology

... suddenly ignite, causing highly destructive flash fires and explosions. New standards on combustible dust require organizations in the chemical, food, and related ...

NFPA 652 - Chilworth Technology

... to evaluate the adequacy of existing controls of dust hazards and to propose practical recommendations for any needed improvements. This includes the identification of possible fire and explosion scenarios and to evaluate the existing or proposed ...

Hazardous Area Electrical Classification - Chilworth Technology

... Should I Use? The risk of fire or explosion is a real concern for sites where flammable liquids, gases and vapors, or combustible dusts are present. Organizations must be vigilant to assure ...

Testing Guide for Management of Flash Fires, Explosion and Runaway Reactions - Chilworth Technology

... Other times it is a hidden layer of dust next to a heat source. With the right ... explosions, runaway reactions, and accidental release of energy and ...

Safe Transfer of Powders into Flammable Liquids - Chilworth Technology

... management must be the prevention of fires and explosions. When processing and ... mist, or combustible dust. These fuels, if mixed with air or other ...

Electrostatic Testing - Chilworth Technology

... Volume Resistivity and Charge Relaxation Time – Powders and Dusts Volume resistivity is a measure of the electrical ... is the primary criterion for classifying powders and dusts as low, moderately, or highly insulating. Insulating materials ...

close more results

As the world's leading one-stop source for industry's process safety and optimization needs, the Chilworth ...

Hughes Environmental

4720 Pinewood Louisville, KY 40218 Tel: 888-845-3952

View company website

... Contact the specialist in Commercial Duct Cleaning. Combustible Dust Explosion Combustible Dust that needs remediated? Let an experienced contractor perform ...

Newson Gale, Inc.

460 Faraday Avenue Bldg C Jackson, NJ 08527 Tel: 732-961-7610

View company website
15 More Results

Knowledge Center | Static Control

... UK the Health and Safety Executive recorded 303 dust explosions over a nine-year period and German records ... 580 million, with the average gross loss for dust explosions costing $1.9 million and dust fires costing $ ...

Static electricity in powder processing operations

... UK the Health and Safety Executive recorded 303 dust explosions over a nine-year period and German records ... 580 million, with the average gross loss for dust explosions costing $1.9 million and dust fires costing $ ...

Pharmaceutical Static Grounding | Combustible Powders | Newson Gale

... the highest reported source of ignition in combustible dust cloud explosions. Tank Truck Filling & Emptying Static electricity can lead ...

Food & Beverage Static Grounding | Newson Gale

... bakeries. As more attention is paid to potential dust cloud explosion hazards and flammable hazards by government regulators, (ATEX & ...

Mobile grounding for tank trucks and vacuum trucks

... when granular polypropylene was being vacuumed from a dust collector into a large vacuum truck. The cause of the explosion was a static spark that discharged from the ...

Ignition Source | Static Electricity | Case Studies | Newson Gale

... newson 2017-05-18T10:56:26+00:00 Dust cloud ignition caused by static electricity Newson Gale’s latest series of articles that contain case studies of fires and explosions caused by static electricity draw attention to the ...

Static Grounding Stories | Grounding Solutions | Newson Gale

... they unloaded various sugars. The cause of the explosion was contributed to a build up of static during the unloading process which ignited sugar dust in the silos. Newson Gale’s contact at ...

Confectionery Manufacturer | Continuous Static Monitoring | Newson Gale

... they unloaded various sugars. The cause of the explosion was contributed to a build up of static during the unloading process which ignited sugar dust in the silos. Newson Gale’s contact at ...

News | Newson Gale

... Inquire Here Mitigating the Risk of Fire and Explosion at Your ... and controlling dust, monitoring for hot spots and arresting sparks when ...

Static electricity in powder processing equipment

... of powders when they are at a Minimum Explosive Concentration. Table 3. MIE of ... a combustible dust deflagration. The safety factor that needs to be ...

IECEx certification in hazardous areas

... and Article 506, added in 2005, relating to dust and fibre atmospheres, describe the Class and Zoning ... do not address Class and Zoning systems for dust and fibre atmospheres, under NEC 506.20, equipment ...

Static Grounding Protection for tank trucks and road tankers

... The vast majority of flammable vapours and combustible dusts can be ignited at these energy levels. For ...

Tank Truck Static Grounding | Earth-Rite RTR | Newson Gale

... a vast range of combustible gases, vapours and dusts. The ignition of such atmospheres by static electricity ... of the transfer operation. *IEC 60079-32-1, “Explosive atmospheres: electrostatic hazards, guidance” *NFPA 77, “Recommended Practice ...

Verified grounding for safety in hazardous locations

... of a vast range of gases, vapors and dusts. To ensure the driver grounds the truck he/ ...

Recommended guidance for grounding in hazardous areas

... contain enough energy to ignite flammable vapours and dusts. Electrostatics is a detailed subject area that, for ... Electricity (2007). Cenelec CLC/TR 60079-32-1: Explosive atmospheres – Part 32-1: Electrostatic hazards, guidance (2015). ...

close more results

Static control for hazardous areas. For over 30 years, Newson Gale has been leading the ...

Jensen Hughes

600 West Fulton Street Suite 500 Chicago, IL 60661 Tel: 410-737-8677

View company website

We are the Choice for Securing the Safety of People and Assets JENSEN HUGHES is the global leader in engineering consulting services for the built environment. ...

Hansentek

4141 Sladeview Crescent Unit 18 Mississauga, ON L5L 5T1 Tel: 905-607-5780

View company website

The Hansentek division of Neola Corporation specializes in the design and manufacture of systems for ...

REMBE GmbH - News

... extensive industry knowledge, Jan is formally certified for Dust Explosion Prevention and Limiting Systems, as an expert in investigating Dust Explosions and in the IECEx Certificate of Personnel Competence. “ ...

REMBE GmbH - Flameless Venting - Q-Box

... Q-­BOX - Cost-effective indoor explosion venting for dust explosions Applications The Q-Box is designed for plant ... The sanitary cover protects the Q-Box against dust from outside sources. Mechanism The Q-Box guarantees safe explosion venting in working areas. Like the Q-Rohr , ...

REMBE GmbH - Explosion Safety and Pressure Relief

... read more... Explosion Safety for dust and metal dust explosions Welcome to REMBE ! We are your partner for ...

Mills and grinding plants

... sources. If you observe the prerequisites for a dust explosion, a mill offers all the necessary components: Dust, a closed container, effective combustion sources and oxygen. Therefore, several mill manufacturers offer devices with an explosion pressure resistant design (up to 10 bar). Not ...

REMBE GmbH - Isolation

... and dust extraction or aspiration lines. If a dust explosion occurs, the flames and pressure waves can spread ...

REMBE GmbH - Explosion Safety - Flameless Venting

... for maximum efficiency. This form of flame- and dust-free explosion venting is the safest and most cost-effective ...

REMBE GmbH - Explosionsafety - Flemeless Venting Q-Rohr®

... for indoor plants that are at risk of dust and gas explosions. Many new plants are equipped directly with the ... or even 3000°C (5432°F) for metal dusts) extremely efficiently. This reduces the volume of gas ejected and extinguishes the explosion. Your advantages Certification Patents: DE 38 22 012; ...

REMBE GmbH - Flameless Venting - Q-Rohr® metal dust

... dusts far exceed those for other types of dust. In the case of an explosion, the temperature can reach approx. 3000 °C (5400 ° ... flameless explosion venting to be certified for metal dusts in accordance ... explosion safety in the metalworking industry. Expensive and complicated ...

Wood processing industries

... in wood processing Industries Wood processing without creating dust is impossible. This is why economic Explosion Safety is a must. Some system parts are ...

REMBE GmbH - Electrostatic Charging Basics

... are handled, or in filling plants for combustible dusts, it is often sufficient to apply adequate measures of Explosion Safety, whereby a particular priority is on the “ ...

Filters / aspiration systems

... with explosion safety devices . The danger of an explosion develops because, in addition to the dust that has been extracted from other system parts, ... filter elements is particularly problematic. The very fine dust then spreads ... lead to an explosion. Filters in indoor areas are therefore vented with ...

Spray dryers

... a constant atmosphere of stirred-up, usually combustible, dust and oxygen. Spray dryers, however, may not be considered as a standalone design element, but must be evaluated as a cohesive complex system . The explosion-related design of spray dryers is specifically regulated ...

Conveyors

... on the degree of fineness, moisture content and dust formation probability of the material, the conveying principle and the conveying speed of the system parts, there will be different explosion risk levels which depend on the zone partitioning ...

REMBE GmbH - Isolation - VENTEX®

... in plants that process combustible dusts (incl. metal dusts), gases or ... using the VENTEX ESI-E/D: Explosion safety with one-way or two-way acting ...

REMBE GmbH - Suppression

... prevent these from being released due to an explosion. In addition, Q-Bic is widely used in all apparatus, ducts and pipes for dusts, gases and hybrid mixtures in the following industrial ...

REMBE GmbH - Isolation - EXKOP® System

... well as operating as a decoupling system for dust-bearing plants, the EXKOP system can also be used as a spark arrester or overpressure limiter. Mechanism In the case of an explosion, the EXKOP controller receives a trigger signal (e. ...

REMBE GmbH - Explosion Safety - Accessories - Signalling

... Reliable protection against penetration by snow, rain and dust with a low ... to the risks of explosion-induced subsequent fires. Downloads send enquiry

Mixers

... Whether a mixer has to be protected against explosions depends on the different properties of the respective mixer. These include In addition to the safety-relevant key data of the dust, the links to other parts of the system ...

Elevators

... protective measures, such as the limitation of the dust concentration through suction devices, should be considered in ... measures are aligned to each other, will your Explosion Safety concept be safe AND economic. We therefore ...

close more results

For 35 years,REMBE Inc. has been a leader in innovation and manufacture of high-quality pressure ...

Baker Engineering and Risk Consultants, Inc.

3330 Oakwell Court Suite 100 San Antonio, TX 78218-3024 Tel: 210-824-5960

View company website
3 More Results

Dust Hazard Analysis (DHA) and Evaluations - BakerRisk

... existed. BakerRisk can assist clients with identifying combustible dust explosion hazards, carrying out a dust hazard analysis (DHA), evaluating whether a facility is ...

Pulp and Paper - BakerRisk

... materials and operations including toxic materials, flammable and explosive materials, dust hazards, corrosion and material failure issues, fire and ...

Brochures - BakerRisk

... Facility Building Design Support Cold Embrittlement Tool Combustible Dust Hazard Evaluation Computational Fluid Dynamics Tools Deflagration Load Generator Due Diligence Studies Evaluating SIP Performance Explosion Hazards in Industry Facility Siting Studies Failure Prevention ...

close more results

... existed. BakerRisk can assist clients with identifying combustible dust explosion hazards, carrying out a dust hazard analysis (DHA), evaluating whether a facility is ...

NFPA

1 Batterymarch Park Quincy, MA 02169-7471 Tel: 617-770-3000

View company website

... 61 Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities NFPA 67 ... 654 Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible ...

Association badge legend
VSVendor Showcase