13 Companies with Results for fire endurance testing 1 - 10 of 13

NGC Testing Services

1650 Military Rd. Buffalo, NY 14217 Tel: 716-873-9750

View company website
2 More Results

Testing Services Update - August 2017

... s floor level. In this furnace we can test the fire endurance of a wide range of assemblies. These include completed roof and floor-ceiling assemblies, columns, beams and building joints. We have even tested subway cars! The furnace meets ASTM E119 requirements ...

Testing Services Update - May 2016

... and a sub-basement for maintenance. We can test a wide range of horizontal assemblies for fire endurance, such as roof assemblies, floor-ceiling assemblies, columns ...

close more results

NGC Testing Services features one of North America's most sophisticated and unique, fully accredited independent ...

METL-SPAN

6050 Santo Road Suite 145 San Diego, CA 92124 Tel: 877-585-9969

View company website
2 More Results

ThermalSafe® Fire Resistant Mineral Wool Panel - Fire Rated Panels, Fire Resistant Panels, Mineral Wool Panels

... for nonbearing walls in accordance with UL 263 Fire Endurance test, 6″ thickness rated for two hour fire resistance ... for nonbearing walls in accordance with UL 263 Fire Endurance tests, and 8″ thickness for three hour fire resistance ...

Tests & Certifications - Metl-Span, Insulated Wall Panels, Roof Panels, Architectural Wall Pane, Insulated Foam Panels

... 1.2.1 Fire Canada CAN/ULC S101 Fire Endurance Tests of Building Construction and Materials One hour non- ... layers of Type X Gypsum CAN/ULC S101 Fire Endurance Tests of Building Construction and Materials Meets 15 minute ...

close more results

... for nonbearing walls in accordance with UL 263 Fire Endurance test, 6″ thickness rated for two hour fire resistance ... for nonbearing walls in accordance with UL 263 Fire Endurance tests, and 8″ thickness for three hour fire resistance ...

QAI Laboratories

8385 White Oak Ave. Rancho Cucamonga, CA 91730 Tel: 704-862-8594

View company website

QAI Laboratories Inc. The Fast Lane to Certification QAI Laboratories Inc. (QAI) is a world ...

Arup

13 Fitzroy Street Suite 200 London, DC W1T 4BQ Tel: 202-729-8230

View company website

Arup is the creative force at the heart of many of the worlds most prominent ...

SAFTI FIRST

100 North Hill Drive Suite 12 Brisbane, CA 94005 Tel: 415-822-4222

View company website
5 More Results

Fire Rated Doors: Standards, Testing and Glazing Requirements

... 20/45/60/90/180 minutes. After the fire endurance test, the test specimen is subjected to the hose ... during the first 30 minutes of a standard fire endurance test. A 250 degree F temperature rise rating is ...

Specifying Fire Rated Glazing - SaftiFirst

... of a standard fire hose) immediately after the fire endurance test. For the assembly to pass, it must sustain ... a material that has met a 60-minute, fire-protective endurance test must be able to provide more protection. This ...

Fire Protective vs Fire Resistive Glazing - SaftiFirst

... protective vs fire resistive glazing, rather on the fire endurance testing. This article focuses on the IBC, NFPA, UL ... category has its own set of performance features, test standards and allowed applications. Simply relying on the fire endurance rating (20, 45, 60, 90, 120 and 180 ...

Fact or Fiction - The Hose Stream Test - SaftiFirst

... constructions having a resistance period indicated in the fire endurance test of less than one hour. The current hose stream exemption for 20-minute assemblies – doors, transoms and sidelites – is consistent with the general exception for fire resistant constructions rated less than one hour. U. ...

The Truth About 60 minute Fire Rated Glass - SaftiFirst

... criteria, and be tested for use under door test standards. FICTION: Where 45-minute rated is required, 60-minute rated glazing is better. FACT: The extra fifteen minutes of fire endurance is not a benefit, says the former NFPA ...

close more results

... 20/45/60/90/180 minutes. After the fire endurance test, the test specimen is subjected to the hose ... during the first 30 minutes of a standard fire endurance test. A 250 degree F temperature rise rating is ...

Niedner, Inc.

675 Merrill St Coaticook, QC J1A2S2 Tel: 819-849-2751

View company website
2 More Results

Niedner | Fire Fighting Hoses

... abrasion resistant fire hoses and products that can endure exposure to ... flow, with a service test pressure rating of 400 PSIG (2800 kPa) Download ...

Niedner | Products

... a better and safer way to do some fire hose testing. See products LATEST NEWS 21/04/2017 Niedner ... contra incendios | Discharge hose | Industrial Fire fighting hose | Fire hose testing | Lay Flat hose | Large Diameter Hose Copyright © 2016 ...

close more results

... abrasion resistant fire hoses and products that can endure exposure to ... flow, with a service test pressure rating of 400 PSIG (2800 kPa) Download ...

RICE Hydro, Inc.

3500 Arrowhead Drive Carson City, NV 89706-2006 Tel: 775-885-1280

View company website

... time? All RICE Hydro products are built to endure the test of time. The average life span of our ... will become familiar with all the benefits of testing fire hose with one of your machines rather than ...

PCI - Promatec

11707 W Sam Houston Pkwy S Suite K Argyle, TX 77271 Tel: 602.312.8260

View company website

... act as pressure seals as well as offering fire endurance. As with all two-part silicones we offer, ... or water-tight integrity alone or coupled with fire resistance is desired for ... exposure testing to assure its stability in nuclear applications. LDSE ...

CST Industries

9701 Renner Boulevard Suite 150 Lenexa, KS 66219 Tel: 713-351-3738

View company website
2 More Results

Glass Fused To Steel Bolted Storage Tanks Manufacturer - CST

... is taken in craftsmanship for a tank that endures the test of time. From the automated manufacturing processes through ...

OptiBond Epoxy Coated Steel Storage Tanks Manufacturer | CST Industries

... years of experience and over 250,000 field-tested applications around the world, no other manufacturer comes close to our level of knowledge of how to apply epoxy coatings and how they endure in some of the harshest environments. CST is ...

close more results

... is taken in craftsmanship for a tank that endures the test of time. From the automated manufacturing processes through ...

Unisource Manufacturing Inc.

8040 NE 33rd Drive Portland, OR 97211 Tel: 503-281-4673

View company website

... Series 2618 is a premium quality, heavy-duty fire engine suction & discharge hose. This hose is designed for severe applications requiring endurance and higher pressure ratings. Full product description Series ...