omni
nfpa

Items per page:
42 Companies with Results for flame spread 1 - 10 of 42

NGC Testing Services

1650 Military Rd. Buffalo, NY 14217 Tel: 716-873-9750

View company website
2 More Results

Testing Services Update - March 2017

... technical aspects of testing. This month we explain flame spread classifications. It is hard to believe that 2017 ... finish materials are classified in accordance with the flame spread index (FSI) and smoke developed index (SDI) results ...

NGC Testing Services

... and cycling and data acquisition system. For evaluating: Flame spread and smoke developed index. For evaluating: Non-combustibility ...

close more results

NGC Testing Services features one of North America's most sophisticated and unique, fully accredited independent ...

Lonza Wood Protection

360 Interstate North Parkway Suite 450 Atlanta, GA 30339 Tel: 678-627-2000

View company website

... FRX(R) exterior FRT wood, which economically reduce flame spread and smoke generation in commercial, institutional, industrial, and ...

Contego International

334 W Greyhound Pass Carmel, IN 46032 Tel: 317-580-0665

View company website
9 More Results

Fire Tests | Dimensional Lumber & Plywood | Contego International

... fire barrier on Dimensional Lumber and Plywood include flame spread and smoke production on douglas fir, toxic gas ... Fire Tests UL – 723 (ASTM E-84, ANSI)“Flame Spread and Smoke Production on Coated Louvered Door Panels ...

Fire Tests | Oriented Strand Board | Contego International Inc.

... fire barrier paint on Oriented Strand Board include flame spread and smoke production on OSB, PMDO and douglas ... 5, NFPA 255 & UBC 8-1 & 42-1) “Flame Spread and Smoke Production on OSB” Location: Intertek Test ...

Fire Tests | Structural Insulated Panels SIPS | Contego International

... fire tests include evaluation of thermal barriers and flame spread and smoke production on OSB and PMDO. ... 5, NFPA 255 & UBC 8-1 & 42-1) “Flame Spread and Smoke Production on OSB” Test Name: ASTM ...

Fire Tests | General Fire Test Data | Contego International Inc.

... 5, NFPA 255 & UBC 8-1 & 42-1) “Flame Spread and Smoke Production on OSB” Location: Intertek Test ... rate of 60 sq. ft./gallon and limited flame spread to 10 and smoke development to 10. Click ...

Fire Safety Tests | International | Contego International Inc.

... 13823 (SBI Method) and EN ISO 11925-2 Flame Spread and Smoke Production Location: SP Technical Research Institute ... report EN 13823: 2010 Test on 12mm OSB Flame spread and smoke production. Location: The BUILDING TEST CENTRE ...

Fire Retardant Paint for Wood | Contego International Inc.

... the test results showed that Contego gets better flame spread and smoke production results on Douglas fir plywood ...

Drywall Fire Protection | Contego International Inc.

... Contego protects the paper fascia while maintaining a flame spread and smoke production rating of 0×0. To ...

Fire Tests | Contego International Inc.

... Standard BS EN 13501-1. This is another flame spread and smoke production test similar to the standard ...

Fire Tests | Canadian Test Data | Contego International Inc.

... coat ever (8 mils dft) and still got Flame Spread and Smoke Production stats of 5×40. Click ...

close more results

... fire barrier on Dimensional Lumber and Plywood include flame spread and smoke production on douglas fir, toxic gas ... Fire Tests UL – 723 (ASTM E-84, ANSI)“Flame Spread and Smoke Production on Coated Louvered Door Panels ...

Rectorseal Corporation

2601 Spenwick Drive Houston, TX 77055 Tel: 713-263-8001

View company website

Worldwide Leader in Firestop Technology - Our family of UL approved Metacaulk® Firestopping Products is ...

Flame Seal Products

15200 West Drive Houston, TX 77053 Tel: 713-668-4291

View company website
5 More Results

Wood Seal ATM - Flameseal

... treated substrate. FAB ASTM E-84 Class A Flame Spread = 25 Smoke Generation = 50 FAQ Wood Seal A™ ... in the ASTM E-84-05 (Steiner Tunnel) flame spread test. Wood Seal™ achieved a Class B fire ...

Wood SealTM - Flameseal

... treated substrate. FAB ASTM E-84 Class B Flame Spread = 35 Smoke Generation = 95 FAQ Wood Seal A™ ... damage to the substrate. It will slow the flame spread and prevent fire from propagating along the treated ...

Leather Seal ConcentrateTM - Flameseal

... greatly reducing smoke generation. It will limit the flame spread, but will not protect the leather directly exposed to the flame from damage. Back to top Search for: Recent ...

Wildfire Protection System by Flame Seal Products - Flameseal

... second dog house is left unprotected. The fire spreads quickly and engulfs the the unprotected dog house ...

Wildfire Season - Be Active Not Reactive - Flameseal

... strong winds, and combustible vegetation allow wildfires to spread up to 14 miles per hour. So far ... by email. Search for: Recent Posts Corporate Address Flame Seal Products Inc. 15200 West Drive Houston, Texas ...

close more results

... treated substrate. FAB ASTM E-84 Class A Flame Spread = 25 Smoke Generation = 50 FAQ Wood Seal A™ ... in the ASTM E-84-05 (Steiner Tunnel) flame spread test. Wood Seal™ achieved a Class B fire ...

TPR 2

36 PLAINS RD. Essex, CT 06426 860-767-8772

UL

333 Pfingsten Rd Northbrook, IL 60062-2096 Tel: 847-664-1851

View company website

... Curtains and Drapes – Detailed Procedure to Determine the Flame Spread of Vertically Oriented Specimens. The standard addresses a method for determining the flame spread of textiles for curtains and drapes by testing ...

Knauf Insulation

One Knauf Drive Shelbyville, IN 46176 Tel: 317-398-4434

View company website
3 More Results

Acoustical Smooth Board | Knauf Insulation

... Burning Characteristics (UL Classified) • Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ... subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented ...

KN Series | Knauf Insulation

... subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented ...

Jet Stream® Ultra Blowing Wool Insulation | Knauf Insulation

... subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented ...

close more results

... Burning Characteristics (UL Classified) • Does not exceed 25 Flame Spread, 50 Smoke Developed when tested in accordance with ... subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented ...

EnviroGuard

5534 Olive St Montclair, CA 91763 Tel: 800-206-9884

View company website

EnviroGuard is the leading manufacturer of global compliance solutions in the standby power industry. We ...

National Gypsum

2001 Rexford Rd Charlotte, NC 28211 Tel: 704-365-7300

View company website

... especially to meet HUD fire safety requirements of flame spread not over 25. When used in furnace room, ...

Association badge legend